Reliability of Radiographic Evaluation in Distal Radius Fractures: Implications for Clinical Practice

Authors

DOI:

https://doi.org/10.56929/jseaortho-2026-0302

Keywords:

Distal Radius Fractures, Interobserver Reliability, Intraclass Correlation Coefficient, Fracture Instability

Abstract

Purpose: To assess the interobserver reliability of standard radiographic parameters in non-operatively managed distal radius fractures.

Methods: Two independent hand and microsurgery specialists evaluated the radiographs. Reliability was assessed using intraclass correlation coefficients (ICCs), Cohen’s kappa, and Bland–Altman plots.

Results: Continuous measurements, including ulnar variance, dorso-volar angulation, and radial inclination, demonstrated excellent reliability (ICC > 0.90). The categorical evaluation of associated ulnar fracture yielded substantial reliability (κ = 0.79).

Conclusions: Continuous radiographic parameters can be applied mostly with confidence in both clinical decision-making and research settings, whereas categorical assessments may warrant more cautious interpretation.

Metrics

Metrics Loading ...

References

Adams AJ, Miller A, Tan E, et al. Reliability of assessing distal radius fractures on a smartphone versus PACS. Hand (N Y) 2024;19:52-7.

Meena S, Sharma P, Sambharia A, et al. Fractures of distal radius: an overview. J Family Med Prim Care 2014;3:325-32.

Pogue DJ, Viegas SF, Patterson RM, et al. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am 1990;15:721-7.

Rajadurai OJ, Chhetri P, Nandagopal D. Radiological parameters and functional outcomes in distal radius fractures: a narrative review. Natl J Clin Anat 2025;14:174-9.

Lafontaine M, Hardy D, Delince P. Stability assessment of distal radius fractures. Injury 1989;20:208-10.

Paasikallio K, Sund R, Miettinen S, et al. Intra- and inter-observer agreement in distal radius fracture dislocation measurement of casting position. Acta Orthop 2023;94:379-86.

Watson NJ, Asadollahi S, Parrish F, et al. Reliability of radiographic measurements for acute distal radius fractures. BMC Med Imaging 2016;16:44.

Ghodasra JH, Yousaf IS, Sanghavi KK, et al. Assessing the relationship between bone density and loss of reduction in nonsurgical distal radius fracture treatment. J Hand Surg Am 2021;46:377-85.e2.

Jung HS, Chun KJ, Kim JY, et al. Necessity of acceptable radiologic alignment by preoperative closed reduction for unstable distal radius fractures treated with volar locking plates. Eur J Trauma Emerg Surg 2021;47:1881-7.

LaMartina J, Jawa A, Stucken C, et al. Predicting alignment after closed reduction and casting of distal radius fractures. J Hand Surg Am 2015;40:934-9.

Mathews JS, Martyn TLB, Rao KS, et al. The volar cortical hinge: an independent risk factor for distal radius fracture displacement. J Wrist Surg 2024;13:222-9.

Kreder HJ, Hanel DP, McKee M, et al. X-ray film measurements for healed distal radius fractures. J Hand Surg Am 1996;21:31-9.

Patel B, Aqil A, Riaz O, et al. The 2nd metacarpal cortical index as a simple screening tool for osteopenia. J Bone Metab 2020;27:261-6.

Warwick D, Prothero D, Field J, et al. Radiological measurement of radial shortening in Colles' fracture. J Hand Surg Br 1993;18:50-2.

Harris PA, Taylor R, Thielke R, et al. Research electronic data capture (REDCap)—a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform 2009;42:377-81.

Harris PA, Taylor R, Minor BL, et al. The REDCap consortium: building an international community of software platform partners. J Biomed Inform 2019;95:103208.

Arifin WN. Sample size calculator (web) [Internet]. 2025 [cited 2025 Apr 11]. Available from: https://wnarifin.github.io/ssc_web.html.

Walter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med 1998;17:101-10.

Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-74.

Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 2016;15:155-63.

Benchoufi M, Matzner-Lober E, Molinari N, et al. Interobserver agreement issues in radiology. Diagn Interv Imaging 2020;101:639-41.

Mantha S, Roizen MF, Fleisher LA, et al. Comparing methods of clinical measurement: reporting standards for Bland and Altman analysis. Anesth Analg 2000;90:593-602.

Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.

StataCorp. Stata Statistical Software: Release 17. College Station (TX): StataCorp LLC; 2021.

Dissaneewate P, Thanavirun P, Tangjaroenpaisan Y, et al. External validation and revision of the Lafontaine criteria for unstable distal radius fractures: a retrospective study. J Orthop Surg Res 2025;20:146.

Stirling E, Jeffery J, Johnson N, et al. Are radiographic measurements of the displacement of a distal radial fracture reliable and reproducible? Bone Joint J 2016;98-B:1069-73.

Saito T, Nakamura T, Nagura T, et al. he effects of dorsally angulated distal radius fractures on distal radioulnar joint stability: a biomechanical study. J Hand Surg Eur Vol 2013;38:739-45.

Alemdaroǧlu KB, Iltar S, Aydoǧan NH, et al. Three-point index in predicting redisplacement of extra-articular distal radial fractures in adults. Injury 2010;41:197-203.

Downloads

Published

2026-08-15

How to Cite

1.
Khajonvittayakul N, Supichyangur K, Apivatgaroon A, Tantiyavarong P. Reliability of Radiographic Evaluation in Distal Radius Fractures: Implications for Clinical Practice. JseaOrtho [Internet]. 2026 Aug. 15 [cited 2026 Aug. 24];. Available from: https://www.jseaortho.org/index.php/jsao/article/view/302

Issue

Section

Original Articles